GF312V2 Portable Three Phase Multifunction Energy Meter Calibrator With 3PCS 120a clamp on ct

Energy Meter Testing
January 20, 2020
Category Connection: 전기 미터 구경측정
The GF312V2 three phase electric meter calibrator is suit for electric power departments, measuring and quality examining departments and electric lab to field use. Three-phase energy meter field calibrator is an advantageous product among electric energy metering series products of the company, and is integrated with energy meter calibrator and low voltage & high voltage metering device, with energy meter error calibration, error wiring judgment, measurement of transformation ratio, meter reading, harmonic measurement and other functions. We make ‘Three Phase Power Energy Meter Calibrator’ which is a source of AC Voltage, AC Current, Power Factor, frequency, time. Thereby it is also a source of VA, VAr, W, VAhr, VArhr, and Whr. 3 Sine waves of AC voltage, 3 Sine waves of AC Current. All these 6 outputs have synchronized frequency. Portable Three Phase KWH Meter Calibrator mainly applied in the meter testing centers of electricity utilities, authoritative energy measurement labs, energy meter manufacturer, authoritative centers for energy meter calibration, and electricity engineering companies.
Features
High accuracy 0.05%
Screen capture function
With 2-63nd harmonics measurement
With 3pcs 120A clamp on ct
Smart scanning head
Input two pulse signal for master and slave meter synchronously calibration
Large size display screen, direct viewing and convenient
Internal communication port for PC control
Multiple power supply for different testing occasion
Large capacity storage device for mass memory
A high brightness, high definition and high resolution 7' TFT color LCD screen shows clearly and beautifully, with large information content and rich content, and the screen shows all the parameters measured on the site.
Single and three phase voltage, current, power, phase, active and reactive power factor, frequency and other parameters can be in real time measured. The energy meter and terminal errors can be calibrated, and single-phase and three-phase electronic induction active and reactive energy meters can be inspected.
The pulse input modes include manual input, photoelectric input and electric pulse input three ways.
The pulse input modes include manual input, photoelectric input and electric pulse input three ways.
A wide range of working power supply is AC50 ~ 500V; the test line, adapter and battery power supply can be chosen respectively, and online charging is available.