색: | 빨강 | 상품 이름: | 5p20 제로 순서 CT 전류 변압기 |
---|---|---|---|
정격 일차 전류: | 50A | 저장 온도: | +70' C에 대한 '-40' C |
일일 평균 임시: | <> | (KG에) 짓누르세요: | 10 |
비율: | 50/5A | Appliction: | 제로 순서 보호 소자 |
지름: | 80 밀리미터, 120 밀리미터, 140 밀리미터, 160 밀리미터 | 재료: | 수지 |
하이 라이트: | Casting Zero Sequence Current Transformer,120mm Zero Sequence Current Transformer,50A Zero Sequence Current Transformer |
LZCK2500-10 120mm 50/5a Resin Casting Split core Protection Zero Sequence Current Transformer 5P20
GFUVE LZCK2500-10 is a zero sequence current transformer, can used wildly,the accuracy up to 10P5 and 10P10 5P20.
The protection current transformer is used to reduce the currents in power systems, producing proportional currents in the unit’s secondary windings that remain isolated from the main circuit. The replica current is then used as an input to a protective relay, which can then automatically isolate part of the power circuit should it experience a fault.
Protection Current Transformers are designed to measure the actual currents in power systems and to produce proportional currents in their secondary windings which are isolated from the main power circuit.
protection cts are used for protection against over current or faulty current, their secondary is
thusconnected to the protection relays and the to the tripping coil. there may be series or shunt
tripmechanism, thus the burden(VA) of protection ct is more as compared to metering cts.
The classification of protection current transformers follows the following simple formula: "10 P10" Manufacturers of protection devices will normally specify the classification for the
protection current transformer intended to operate the particular protection device concerned.
This is required for protection CT, because the fault current is high and the CT should be able tosense the high fault current accurately to protect the system. The common numbers are 10, 15, 20 and 30. Class PS: PS is for 'Protection Special'. This class of CT's are used for special
Protection such as differential protection, distance
Parameters
Technical parameters | |
Standards | IEC60044; IEC 61869; ANSI/IEEE C57.13 |
Rated primary current | 50-600A |
Rated load | ≤30VA |
Rated frequency | 50Hz or 60Hz |
Rated secondary current | 5A or 1A |
Rated short-time thermal current | 40kA, 1S |
Rated dynamic current | 63kA |
Rated insulation level | 12/42/75KV |
FS | ≤10 |
Mechanical parameters | |
Material | Epoxy resin |
Weight (kg) | 18 |
Operating conditions | |
Operating temperature | -10°C to +55°C |
Daily average temp | <+40°C |
Storage temperature | -40°C to +70°C |
Altitude | <1000 meters |
Condition | No existence of severely begrimed, erosive and radioactive gas in the air. Permission of long-term operation under rated current. |
Technical Data
Rated Current Ratio | Accuracy Class | Rated Output(VA) |
50/1 | 10P5 | 2 |
60/1 | 2 | |
75/1 | 2 | |
100/1 | 2 | |
150/1 | 10P10 | 2.5 |
200-300/1 | 2.5 | |
400-600/1 | 2.5 | |
50/5 | 10P5 | 5 |
75/5 | ||
100/5 | 10 | |
150-300/5 | 10P10 | 20 |
350-600/5 | 30 |